940.569.4116

Packaged Air Cooled Chiller

Packaged Chillers
Product Line: SA-Series
Capacity Range: 1.5 to 20 Ton

Standard Features

  • High Efficient R-410A Refrigerant
  • Copeland Scroll compressor(s)
  • Insulated stainless steel copper-brazed plate evaporator(s) (others available)
  • Cast iron end suction centrifugal supply pump rated at 2.4gpm per ton at 100’TDH (stainless available)
  • Insulated polypropylene reservoir with fill port and liquid level sight glass (larger volumes available)
  • Thermostatic expansion valve, filter drier, sight glass installed on refrigerant circuit(s)
  • Service ports and valves
  • NEMA 4 control panel with digital temperature controller
  • High and low pressure safety
  • Single point power connection
  • Direct drive fan(s) made to run slower and more quiet
  • Vertical air discharge fans minimizes operating sound
  • Weather resistant fan motor made to survive in the elements.
  • Highly efficient coil provides excellent heat transfer and low air resistance
  • Energy Star qualified unit
  • Assembled, plumbed, and wired on industrial epoxy-coated steel frame
  • Refrigerant circuit(s) pressure tested for leaks with nitrogen charge
  • Refrigerant circuit(s) vacuum tested for leaks to negative-psi pressure
  • Refrigerant circuit(s) fully charged with refrigerant
  • Hydronic circulation loop leak tested under full flow using the WHALE-SOFT™ Testing Platform
  • Complete systems fully run tested under heat load using the WHALE-SOFT™ Testing Platform

Capacity Chart

Tonnage at
Standard Conditions
Model Leaving Glycol
Temperature
90°F Ambient 100°F Ambient 110°F Ambient
BTU/hr Tonnage BTU/hr Tonnage BTU/hr Tonnage
1.5 SA1.5 25°F/-3.9°C 10,100 0.84 9,265 0.77 8,405 0.70
45°F/7.2°C 15,900 1.33 14,850 1.24 13,700 1.14
65°F/18.3°C 23,600 1.97 22,150 1.85 20,600 1.72
2 SA2 25°F/-3.9°C 13,300 1.11 12,400 1.03 11,350 0.95
45°F/7.2°C 20,500 1.71 19,150 1.60 17,750 1.48
65°F/18.3°C 30,000 2.50 28,100 2.34 26,200 2.18
3 SA3 25°F/-3.9°C 20,450 1.70 18,700 1.56 16,900 1.41
45°F/7.2°C 31,850 2.65 29,750 2.48 27,500 2.29
65°F/18.3°C 46,600 3.88 43,900 3.66 41,100 3.43
4 SA4 25°F/-3.9°C 28,250 2.35 26,250 2.19 24,000 2.00
45°F/7.2°C 43,000 3.58 40,350 3.36 37,450 3.12
65°F/18.3°C 62,600 5.22 58,800 4.90 54,900 4.58
5 SA5 25°F/-3.9°C 36,050 3.00 33,450 2.79 30,700 2.56
45°F/7.2°C 55,400 4.62 51,750 4.31 48,050 4.00
65°F/18.3°C 81,000 6.75 76,000 6.33 71,000 5.92
6 SA6
SA6D
25°F/-3.9°C 40,400 3.37 36,950 3.08 33,050 2.75
45°F/7.2°C 62,500 5.21 58,500 4.88 54,250 4.52
65°F/18.3°C 92,000 7.67 86,750 7.23 81,250 6.77
7.5 SA7.5 25°F/-3.9°C 57,750 4.81 53,950 4.50 49,850 4.15
45°F/7.2°C 84,750 7.06 79,500 6.63 74,250 6.19
65°F/18.3°C 120,000 10.00 114,000 9.50 107,000 8.92
8 SA8D 25°F/-3.9°C 56,500 4.71 52,500 4.38 48,000 4.00
45°F/7.2°C 86,000 7.17 80,700 6.73 74,900 6.24
65°F/18.3°C 125,200 10.43 117,600 9.80 109,800 9.15
10 SA10
SA10D
25°F/-3.9°C 72,100 6.01 66,900 5.58 61,400 5.12
45°F/7.2°C 110,800 9.23 103,500 8.63 96,100 8.01
65°F/18.3°C 162,000 13.50 152,000 12.67 142,000 11.83
12.5 SA12.5D 25°F/-3.9°C 80,800 6.73 73,900 6.16 66,100 5.51
45°F/7.2°C 125,000 10.42 117,000 9.75 108,500 9.04
65°F/18.3°C 184,000 15.33 173,500 14.46 162,500 13.54
15 SA15D 25°F/-3.9°C 115,500 9.63 107,900 8.99 99,700 8.31
45°F/7.2°C 169,500 14.13 159,000 13.25 148,500 12.38
65°F/18.3°C 240,000 20.00 228,000 19.00 214,000 17.83
20 SA20D 25°F/-3.9°C 140,500 11.71 131,000 10.92 120,500 10.04
45°F/7.2°C 211,500 17.63 199,000 16.58 187,000 15.58
65°F/18.3°C 308,000 25.67 290,000 24.17 272,000 22.67

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*

1.5 Ton to 5 Ton Specifications (1-Phase & 3-Phase)

Air Cooled Packaged Chillers - 1.5 Ton to 5 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
380-415V/3ph
FLA/MCA/MOCP at
575-600V/3ph
SA1.5 1.5 18,000 5.3 1 36"L x 36"W x 64"H 450 lbs 1HP 30 1" 24.3 / 30.4 / 60 N/A N/A N/A N/A
SA2 2 24,000 7.0 1 36"L x 36"W x 64"H 470 lbs 1HP 30 1" 26.3 /33.88 / 60 N/A N/A N/A N/A
SA3 3 36,000 10.5 1 36"L x 36"W x 72"H 530 lbs 1HP 30 1" 29.2 / 36.6 / 60 16.3 / 20.4 /30 9.04 / 11.3 / 30 11.1 / 13.9 / 30 6.6 / 8.2 / 30
SA4 4 48,000 14.1 1 36"L x 36"W x 72"H 560 lbs 1HP 30 1" 35.9 / 44.9 / 60 21.6 / 27.0 / 30 10.0 / 12.5 /30 12.1 / 15.1 / 30 8.0 / 10.0 / 30
SA5 5 60,000 17.6 1 36"L x 36"W x 74"H 585 lbs 1HP 30 1" 42.3 / 52.88 / 60 24 / 30 / 30 11.6 / 14.5 / 30 14 / 17.6 / 30 9.0 / 11.3 / 30

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*
*Larger tank and pump sizes available*

6 Ton to 10 Ton Specifications (1-Phase)

Air Cooled Packaged Chillers - 6 Ton to 10 Ton Single Phase
Model Tons BTU/hr kW of
Heat Removal
Refrig
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
380-415V/3ph
FLA/MCA/MOCP at
575-600V/3ph
SA6D 6 72,000 21.1 2 72"L x 40"W x 64"H 1050 lbs 1HP 40/100 1.25" 49.6 / 62 / 100 N/A N/A N/A N/A
SA8D 8 96,000 28.1 2 72"L x 40"W x 72"H 1100 lbs 2HP 40/100 1.25" 80.8 / 101 / 150 N/A N/A N/A N/A
SA10D-2 10 120,000 35.2 2 72"L x 40"W x 68"H 1250 lbs 2HP 40/100 1.25" 77.8 / 97.3 / 100 N/A N/A N/A N/A

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*
*Larger tank and pump sizes available*

6 Ton to 7.5 Ton Specifications (3-Phase)

Air Cooled Packaged Chillers - 6 Ton to 7.5 Ton Three Phase
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
380-415V/3ph
FLA/MCA/MOCP at
575-600V/3ph
SA6 6 72,000 21.1 1 48"L x 48"W x 84"H 950 lbs 1HP 30 1.25" N/A 27.6 / 34.5 / 60 13.8 / 17.3 / 30 16.7 / 20.9 / 30 10.6 / 13.3 / 30
SA7.5 7.5 90,000 26.4 1 48"L x 48"W x 84"H 1000 lbs 2HP 30 1.25" N/A 37.7 / 47.1 / 60 18.1 / 22.6 / 30 21.9 / 27.4 / 30 13.7 / 17.1 / 30

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*
*Larger tank and pump sizes available*

10 Ton to 12.5 Ton Specifications (3-Phase)

Air Cooled Packaged Chillers - 10 Ton to 12.5 Ton Three Phase
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
380-415V/3ph
FLA/MCA/MOCP at
575-600V/3ph
SA10 10 120,000 35.2 1 68"L x 44"W x 84"H 1200 lbs 2HP 40/100 1.25" N/A 46.5 / 58.1 / 60 22.6 / 28.3 / 30 27.4 / 34.2 / 60 17.7 / 22.1 / 30
SA10D 10 120,000 35.2 2 68"L x 44"W x 84"H 1632 lbs 2HP 40/100 1.25" N/A 46.5 / 58.1 / 60 22.6 / 28.3 / 30 27.4 / 34.2 / 60 16.9 / 21.1 / 30
SA12.5D 12.5 150,000 44.0 2 68"L x 44"W x 84"H 1632 lbs 2HP 40/100 1.25" N/A 55.5 / 69.4 / 100 29.8 / 37.3 / 60 36.1 / 45.1 / 60 21.3 / 26.6 / 30

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*
*Larger tank and pump sizes available*

15 Ton to 20 Ton Specifications (3-Phase)

Air Cooled Packaged Chillers - 15 Ton to 20 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
380-415V/3ph
FLA/MCA/MOCP at
575-600V/3ph
SA15D 15 180,000 52.7 2 89"L x 68"W x 84"H 2500 lbs 3HP 100 1.5" N/A 73.3 / 91.6 / 100 36.2 / 42.3 / 60 43.8 / 54.8 / 60 27.3 / 34.1 / 60
SA20D 20 240,000 70.3 2 89"L x 68"W x 84"H 2500 lbs 3HP 100 1.5" N/A 84.5 / 105.6 / 150 45.2 / 56.4 / 60 54.7 / 68.4 / 100 34.1 / 42.6 / 60

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  95°F/35°C Ambient Temperature, 0% Glycol*
*Larger tank and pump sizes available*

Request a Quote