940.569.4116

Packaged Water Cooled Chiller System

packaged water cooled chillers
Product Line: SW-Series
Capacity Range: 1.0 to 80 Ton

Standard Features

  • Fabricated from industrial grade American steel coated with 2-Part Epoxy for rust prevention
  • Nema-4 Control Panel with digitial temperature controller
  • Compressor run indicator lights (1ea per Compressor)
  • Digital readout compressor amp draw indicators (1ea per Compressor)
  • Cast iron end suction centrifugal supply pump rated at 2.4gpm per ton at 100’TDH (stainless available)
  • High pressure relief valve (fixed)
  • High pressure cut-out switch (fixed)
  • Loss of charge cut-out switch (fixed)
  • Low pressure cut-out switch (adjustable)
  • Compressor thermal protection (1ea per Compressor)
  • Insulated polypropylene reservoir with fill port and liquid level sight glass (larger volumes available)
  • Copeland Scroll compressor(s)
  • Insulated stainless steel copper-brazed plate evaporator (others available)
  • Stainless steel copper-brazed plate condenser (others available)
  • Rated for indoor use only
  • Single point power connection
  • Refrigerant circuit(s) pressure tested for leaks with nitrogen charge
  • Refrigerant circuit(s) vacuum tested for leaks to negative-psi pressure
  • Refrigerant circuit(s) fully charged with refrigerant
  • Hydronic circulation loop leak tested under full flow using the WHALE-SOFT™ Testing Platform
  • Complete systems fully run tested under heat load using the WHALE-SOFT™ Testing Platform

Capacity Chart

Tonnage at
Standard Conditions
Model Leaving Glycol
Temperature
90°F Condensing Water Inlet Temp 100°F Condensing Water Inlet Temp 110°F Condensing Water Inlet Temp
BTU/hr Tonnage BTU/hr Tonnage BTU/hr Tonnage
1 SW1 25°F/-3.9°C 10,100 0.84 9,265 0.77 8,405 0.70
45°F/7.2°C 15,900 1.33 14,850 1.24 13,700 1.14
65°F/18.3°C 23,600 1.97 22,150 1.85 20,600 1.72
1.5 SW1.5 25°F/-3.9°C 13,300 1.11 12,400 1.03 11,350 0.95
45°F/7.2°C 20,500 1.71 19,150 1.60 17,750 1.48
65°F/18.3°C 30,000 2.50 28,100 2.34 26,200 2.18
2 SW2 25°F/-3.9°C 15,700 1.31 14,400 1.20 12,900 1.08
45°F/7.2°C 24,400 2.03 22,850 1.90 21,100 1.76
65°F/18.3°C 36,000 3.00 33,900 2.83 31,700 2.64
3 SW3 25°F/-3.9°C 23,900 1.99 22,200 1.85 20,500 1.71
45°F/7.2°C 36,800 3.07 34,400 2.87 31,950 2.66
65°F/18.3°C 53,500 4.46 50,300 4.19 46,900 3.91
4 SW4 25°F/-3.9°C 29,500 2.46 27,450 2.29 25,250 2.10
45°F/7.2°C 45,000 3.75 42,200 3.52 39,300 3.28
65°F/18.3°C 65,700 5.48 62,050 5.17 58,200 4.85
5 SW5 25°F/-3.9°C 40,400 3.37 36,950 3.08 33,050 2.75
45°F/7.2°C 62,500 5.21 58,500 4.88 54,250 4.52
65°F/18.3°C 92,000 7.67 86,750 7.23 81,250 6.77
7.5 SW7.5 25°F/-3.9°C 60,500 5.04 56,500 4.71 51,850 4.32
45°F/7.2°C 91,500 7.63 85,950 7.16 80,300 6.69
65°F/18.3°C 134,000 11.17 125,750 10.48 117,250 9.77
10 SW10
SW10DT
25°F/-3.9°C 82,800 6.90 75,800 6.32 68,800 5.73
45°F/7.2°C 126,000 10.50 117,500 9.79 109,000 9.08
65°F/18.3°C 179,500 14.96 170,750 14.23 160,750 13.40
12.5 SW12.5
SW12.5DT
25°F/-3.9°C 104,750 8.73 98,250 8.19 91,500 7.63
45°F/7.2°C 157,500 13.13 148,500 12.38 138,500 11.54
65°F/18.3°C 230,500 19.21 216,500 18.04 202,500 16.88
15 SW15DT 25°F/-3.9°C 123,500 10.29 115,000 9.58 106,750 8.90
45°F/7.2°C 185,500 15.46 175,000 14.58 163,000 13.58
65°F/18.3°C 265,500 22.13 251,500 20.96 236,500 19.71
20 SW20DT 25°F/-3.9°C 165,500 13.79 151,500 12.63 137,500 11.46
45°F/7.2°C 252,000 21.00 235,500 19.63 218,000 18.17
65°F/18.3°C 359,000 29.92 341,500 28.46 321,000 26.75
25 SW25DT 25°F/-3.9°C 207,000 17.25 193,500 16.13 180,000 15.00
45°F/7.2°C 311,000 25.92 292,500 24.38 273,000 22.75
65°F/18.3°C 455,000 37.92 427,000 35.58 398,500 33.21
30 SW30DT 25°F/-3.9°C 243,000 20.25 227,000 18.92 210,000 17.50
45°F/7.2°C 366,000 30.50 345,000 28.75 322,000 26.83
65°F/18.3°C 525,000 43.75 497,500 41.46 467,000 38.92
40 SW40DT 25°F/-3.9°C 317,000 26.42 297,500 24.79 277,500 23.13
45°F/7.2°C 476,000 39.67 449,000 37.42 420,500 35.04
65°F/18.3°C 689,000 57.42 651,000 54.25 612,000 51.00
50 SW50DT 25°F/-3.9°C 393,000 32.75 367,500 30.63 340,000 28.33
45°F/7.2°C 598,000 49.83 563,000 46.92 526,000 43.83
65°F/18.3°C 860,000 71.67 815,000 67.92 767,000 63.92
60
SW60DT
25°F/-3.9°C 506,000 42.17 474,000 39.50 439,000 36.58
45°F/7.2°C 769,000 64.08 723,000 60.25 675,500 56.29
65°F/18.3°C 1,110,000 92.50 1,046,500 87.21 979,500 81.63
70
SW70DT
25°F/-3.9°C 575,000 47.92 535,500 44.63 497,000 41.42
45°F/7.2°C 870,000 72.50 814,000 67.83 758,000 63.17
65°F/18.3°C 1,279,000 106.58 1,199,500 99.96 1,120,500 93.38
80 SW80DT 25°F/-3.9°C 634,000 52.83 591,500 49.29 548,500 45.71
45°F/7.2°C 961,000 80.08 898,500 74.88 836,000 69.67
65°F/18.3°C 1,411,000 117.58 1,324,000 110.33 1,236,500 103.04

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*

1.0 Ton to 7.5 Ton Specifications (1-Phase & 3-Phase)

Water Cooled Packaged Chillers - 1.0 Ton to 7.5 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
575V/3ph
FLA/MCA/MOCP at
380-415V/3ph
SW1 1 12,000 3.5 1 36"L x 36"W x 63"H 394 lbs 1HP 30 1" 18.7 / 23.4 / 30 N/A N/A N/A N/A
SW1.5 1.5 18,000 5.3 1 36"L x 36"W x 63"H 393 lbs 1HP 30 1" 20.0 / 25.0 / 30 11.4 / 14.3 / 30 5.3 / 6.6 / 30 4.4 / 5.5 / 30 5.4 / 6.8 / 30
SW2 2 24,000 7.0 1 36"L x 36"W x 63"H 394 lbs 1HP 30 1" 21.0 / 26.3 / 30 12.2 / 15.3 / 30 5.8 / 7.3 / 30 4.7 / 5.9 / 30 6 / 7.5 / 30
SW3 3 36,000 10.5 1 36"L x 36"W x 63"H 429 lbs 1HP 30 1" 24.8 / 31.0 / 60 15.2 / 19.0 / 30 7.2 / 9.0 / 30 5.9 / 7.4 / 30 7.3 / 9.1 / 30
SW4 4 48,000 14.1 1 36"L x 36"W x 63"H 431 lbs 1HP 30 1" 26.7 / 33.4 / 60 15.7 / 19.6 / 30 7.6 / 9.5 / 30 6.1 / 7.6 / 30 7.8 / 9.7 / 30
SW5 5 60,000 17.6 1 36"L x 36"W x 63"H 434 lbs 1HP 30 1" 32.8 / 40.9 / 60 18.2 / 22.7 / 30 9.4 / 11.8 / 30 7.1 / 8.9 / 30 9.0 / 11.3 / 30
SW7.5 7.5 90,000 26.4 1 36"L x 36"W x 63"H 457 lbs 2HP 30 1.5" N/A 28.7 / 35.9 / 60 14.0 / 17.5 / 30 11.4 / 14.3 / 30 14.8 / 18.5 / 30

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*
*Larger tank and pump sizes available*

10 Ton to 15 Ton Specifications (3-Phase)

Water Cooled Packaged Chillers - 10 Ton to 15 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
575V/3ph
FLA/MCA/MOCP at
380-415V/3ph
SW10 10 120,000 35.2 1 56"L x 44"W x 66"H 727 lbs 3HP 100 1.5" N/A 34.4 / 43.0 / 60 16.8 / 21.0 / 30 12.7 / 15.9 / 30 17.1 / 21.4 / 30
SW10DT 10 120,000 35.2 2 56"L x 44"W x 66"H 809 lbs 3HP 100 1.5" N/A 34.9 / 43.6 / 60 16.8 / 21.0 / 30 13.6 / 17.0 / 30 17.0 / 21.3 / 30
SW12.5 12.5 150,000 44.0 1 56"L x 44"W x 66"H 768 lbs 3HP 100 1.5" N/A 45.3 / 56.6 / 60 23.6 / 29.5 / 30 20.0 / 25.0 / 30 20.7 / 25.9 / 30
SW12.5DT 12.5 150,000 44.0 2 56"L x 44"W x 66"H 808 lbs 3HP 100 1.5" N/A 43.6 / 54.5 / 60 21.2 / 26.5 / 30 18.5 / 23.1 / 30 21.6 / 27.0 / 30
SW15DT 15 180,000 52.7 2 56"L x 44"W x 66"H 887 lbs 3HP 100 2" N/A 52.8 / 66.0 / 100 25.7 /32.1 / 60 20.6 / 25.8 / 30 27.0 / 33.8 / 60

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*
*Larger tank and pump sizes available*

20 to 30 Ton Specifications (3-Phase)

Water Cooled Packaged Chillers - 20 Ton to 30 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
575V/3ph
FLA/MCA/MOCP at
380-415V/3ph
SW20DT 20 240,000 70.3 2 64"L x 50"W x 70"H 1195 lbs 3HP 150 2" N/A 64.2 / 80.3 / 100 31.4 / 39.3 / 60 23.9 / 29.9 / 30 31.4 / 39.3 / 60
SW25DT 25 300,000 87.9 2 64"L x 50"W x 70"H 1213 lbs 3HP 150 2" N/A 79.7 / 99.6 / 100 39.1 / 48.9 / 60 31.3 / 39.1 / 60 38.5 / 48.1 / 60
SW30DT 30 360,000 105.5 2 64"L x 50"W x 70"H 1247 lbs 5HP 150 2" N/A 105.5 / 131.9 / 150 51.7 / 64.6 / 100 41.4 / 51.8 / 60 50.1 / 62.6 / 100

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*
*Larger tank and pump sizes available*

40 to 50 Ton Specifications (3-Phase)

Water Cooled Packaged Chillers - 40 Ton to 50 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
575V/3ph
FLA/MCA/MOCP at
380-415V/3ph
SW40DT 40 480,000 140.6 2 72"L x 60"W x 82"H 1775 lbs 5HP 200 3" N/A 118.2 / 147.8 / 150 55.5 / 69.4 / 100 44.4 / 55.5 / 60 56.2 / 70.3 / 100
SW50DT 50 600,000 175.8 2 72"L x 60"W x 82"H 1868 lbs 5HP 200 3" N/A 138.2 / 172.8 / 200 67.9 / 84.9 / 100 54.4 / 68.0 / 100 69.1 / 86.4 / 100

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*
*Larger tank and pump sizes available*

60 Ton to 80 Ton Specifications (3-Phase)

Water Cooled Packaged Chillers - 60 Ton to 80 Ton
Model Tons BTU/hr kW of
Heat Removal
Refrigeration
Circuits
Dimensions
L x W x H
Shipping
Weight
Process
Pump
Tank
Volume
(in gallons)
Inlet
Outlet
FLA/MCA/MOCP at
208-240V/1ph
FLA/MCA/MOCP at
208-240V/3ph
FLA/MCA/MOCP at
440-480V/3ph
FLA/MCA/MOCP at
575V/3ph
FLA/MCA/MOCP at
380-415V/3ph
SW60DT 60 720,000 211.0 2 84"L x 60"W x 88"H 2346 lbs 7.5HP 300 3" N/A 183.8 / 229.8 / 250 90.1 / 112.6 / 150 72.3 / 90.4 / 100 94.5 / 118.1 /150
SW70DT 70 840,000 246.1 2 84"L x 60"W x 88"H 2473 lbs 10HP 300 3" N/A N/A 103.3 / 129.1 / 150 82.4 / 103 / 150 108.2 / 135.3 / 150
SW80DT 80 960,000 281.3 2 84"L x 60"W x 88"H 2562 lbs 10HP 300 3" N/A N/A 112.0 / 140.0 / 150 90.6 / 113.3 / 150 117.3 / 146.6 / 150

*Standard Site Conditions:  50°F/10°C Leaving Water/Glycol Temperature,  85°F/29.4°C Condenser Water Inlet Temperature, 0% Glycol*
*Larger tank and pump sizes available*

Request a Quote

Have a Question?