The RAR-Series Multi-Condenser Split Systems
The RAR-Series manufactured by Whaley Products, Inc. is a multi-condenser split air-cooled chiller system for industrial cooling. This system is best suited for customers in low ambient environments that require running just straight water for the process fluid and the heat from the condenser needs to be dissipated outdoors. Frequently multiple SAR-Series units are selected in conjunction with a C-Series heat transfer pump tank system to provide high redundancy for critical heat load applications. The RAR-Series multi-condenser split systems are typically purchased initially with a multiple air-cooled condensers with a heat transfer pump tank to start with. With the initial setup, WPI can size the heat transfer pump tank system for unlimited capacity. One of the benefits of the SAR-Series is its redundancy. By using multiple condensers, it gives the high redundancy you need for critical heat load applications that cannot have any downtime. This system can be used for any heat load applications due to having no restrictions on capacity. The heat transfer pump tank system’s reservoir can be sized for whatever your desired volume is which gives you more temperature stability as well as the ability to “store btu/hr” to help minimize chiller size. The SAR-Series coupled with the C-Series Heat Transfer Pump Tank System also allows for multiple configurations and flexible design. WPI can provide but are not limited to redundant pumps, variable frequency drives, different tank materials, different plumbing materials (including those for food applications), and many more.
RAR-Series Multi-Condenser Split Chiller
This complete system is made up of Split Air-Cooled Condenser Units and a Heat Transfer Pump Tank Skid. Air-Cooled Condenser Units are included and are typically installed outdoors in order to deflect the heat to the outside atmosphere. The single Heat Transfer Pump Tank Skid (HTPTS) will be used in conjunction with the Air-Cooled Condenser Units. The HTPTS is typically installed indoors, and contains evaporator(s), refrigerant liquid and suction line components, water/glycol reservoir, pumps, and controls. One pump (chiller circulation pump) circulates the chillers' evaporators to keep the chiller system's reservoir tank at the target set point temperature. The other pump (process supply pump) pulls out of the chiller system's reservoir, circulates to your downstream application, and returns back to the chiller system's reservoir.
RAR-Series System Configurations
RAR-Series Multi-Condenser Split Systems by Capacity
Use this chart to browse our RAR-Series multi-condenser split air-cooled chiller models with two, three, four or five condensing units.
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR3D-X-2P100T2E | 3 | 2 | 7.2 | 100 |
RAR4.5T-X-2P100T3E | 4.5 | 3 | 10.8 | 100 |
RAR6Q-X-2P100T4E | 6 | 4 | 14.4 | 100 |
RAR4D-X-2P100T2E | 4 | 2 | 9.6 | 100 |
RAR6T-X-2P100T3E | 6 | 3 | 14.4 | 100 |
RAR6D-X-2P100T2E | 6 | 2 | 14.4 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR8Q-X-2P100T4E | 8 | 4 | 19.2 | 100 |
RAR8D-X-2P100T2E | 8 | 2 | 19.2 | 100 |
RAR9T-X-2P100T3E | 9 | 3 | 21.6 | 100 |
RAR10D-X-2P100T2E | 10 | 2 | 24 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR12Q-X-2P100T4E | 12 | 2 | 7.2 | 100 |
RAR12T-X-2P100T3E | 12 | 3 | 10.8 | 100 |
RAR12D-X-2P100T2E | 12 | 4 | 14.4 | 100 |
RAR15T-X-2P100T3E | 15 | 2 | 9.6 | 100 |
RAR15D-X-2P100T2E | 15 | 3 | 14.4 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR16Q-X-2P100T4E | 16 | 4 | 38.4 | 100 |
RAR18T-X-2P150T3E | 18 | 3 | 43.2 | 150 |
RAR20Q-X-2P100T4E | 20 | 4 | 48 | 100 |
RAR20D-X-2P100T2E | 20 | 2 | 48 | 100 |
RAR20D-X-2P100T4E | 20 | 2 | 48 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR22.5T-X-2P150T3E | 22.5 | 3 | 54 | 150 |
RAR24Q-X-2P100T2E | 24 | 4 | 57.6 | 150 |
RAR25D-X-2P150T2E | 25 | 2 | 60 | 150 |
RAR25D-X-2P150T4E | 25 | 2 | 60 | 150 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR30Q-X-2P150T4E | 30 | 4 | 72 | 150 |
RAR30T-X-2P150T3E | 30 | 3 | 72 | 150 |
RAR30D-X-2P150T2E | 30 | 2 | 72 | 150 |
RAR30D-X-2P150T4E | 30 | 2 | 72 | 150 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR37.5T-X-2P200T3E | 37.5 | 3 | 90 | 200 |
RAR40Q-X-2P200T4E | 40 | 4 | 96 | 200 |
RAR40D-X-2P200T2E | 40 | 2 | 96 | 200 |
RAR40D-X-2P200T4E | 40 | 2 | 96 | 200 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR45T-X-2P305T3E | 45 | 3 | 108 | 305 |
RAR50Q-X-2P305T4E | 50 | 4 | 120 | 305 |
RAR50D-X-2P305T2E | 50 | 2 | 120 | 305 |
RAR50D-X-2P305T4E | 50 | 2 | 120 | 305 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR60Q-X-2P305T4E | 60 | 4 | 144 | 305 |
RAR60T-X-2P305T3E | 60 | 3 | 144 | 305 |
RAR60D-X-2P305T2E | 60 | 2 | 144 | 305 |
RAR60D-X-2P305T4E | 60 | 2 | 144 | 305 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR75T-X-2P500T3E | 75 | 3 | 180 | 500 |
RAR75T-X-2P500T6E | 75 | 3 | 180 | 500 |
RAR80Q-X-2P500T4E | 80 | 4 | 192 | 500 |
RAR80D-X-2P500T2E | 80 | 2 | 192 | 500 |
RAR80D-X-2P500T4E | 80 | 2 | 192 | 500 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR90T-X-2P500T3E | 90 | 3 | 216 | 500 |
RAR90T-X-2P500T6E | 90 | 3 | 216 | 500 |
RAR100F-X-2P500T5E | 100 | 5 | 240 | 500 |
RAR100Q-X-2P500T4E | 100 | 4 | 240 | 500 |
RAR100D-X-2P500T2E | 100 | 2 | 240 | 500 |
RAR100D-X-2P500T4E | 100 | 2 | 240 | 500 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR120S-X-2P750T6E | 120 | 6 | 288 | 750 |
RAR120Q-X-2P750T4E | 120 | 4 | 288 | 750 |
RAR120T-X-2P750T3E | 120 | 3 | 288 | 750 |
RAR120T-X-2P750T6E | 120 | 3 | 288 | 750 |
RAR130D-X-2P750T2E | 130 | 2 | 312 | 750 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR140D-X-2P750T4E | 140 | 2 | 336 | 750 |
RAR150T-X-2P750T3E | 150 | 3 | 360 | 750 |
RAR150T-X-2P750T6E | 150 | 3 | 360 | 750 |
RAR160Q-X-2P1000T4E | 160 | 4 | 384 | 1000 |
RAR160D-X-2P1000T4E | 160 | 2 | 384 | 1000 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR180D-X-2P1000T4E | 180 | 2 | 432 | 1000 |
RAR195T-X-2P1000T3E | 195 | 3 | 468 | 1000 |
RAR200Q-X-2P1000T4E | 200 | 4 | 480 | 1000 |
RAR200Q-X-2P1000T8E | 200 | 4 | 480 | 1000 |
RAR200D-X-2P1000T4E | 200 | 2 | 480 | 1000 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR210T-X-2P1550T6E | 210 | 3 | 504 | 1550 |
RAR230D-X-2P1550T4E | 230 | 2 | 552 | 1550 |
RAR240T-X-2P1550T6E | 240 | 3 | 576 | 1550 |
RAR260Q-X-2P1550T4E | 260 | 4 | 624 | 1550 |
RAR260D-X-2P1550T4E | 260 | 2 | 624 | 1550 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR270T-X-2P1550T6E | 270 | 3 | 648 | 1550 |
RAR280Q-X-2P1550T8E | 280 | 4 | 672 | 1550 |
RAR300T-X-2P1550T6E | 300 | 3 | 720 | 1550 |
RAR320Q-X-2P2100T8E | 320 | 4 | 768 | 2100 |
RAR345T-X-2P2100T6E | 345 | 2 | 828 | 2100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR360Q-X-2P2100T8E | 360 | 4 | 864 | 2100 |
RAR390T-X-2P2100T6E | 390 | 3 | 936 | 2100 |
RAR400Q-X-2P2100T8E | 400 | 4 | 960 | 2100 |
RAR460Q-X-2P2500T8E | 460 | 4 | 1104 | 2500 |
RAR520Q-X-2P2500T8E | 520 | 4 | 1248 | 2500 |
Contact a Whaley Sales Engineer today for more information.
Standard Features
Insulated stainless steel copper-brazed plate evaporator(s) (Cupre Nickel available)
High Efficient R-410A Refrigerant
Copeland Scroll compressor(s)
Thermostatic expansion valve, filter drier, sight glass installed on refrigerant lines
Service ports and valves
Single point power connection
Direct drive fan(s) made to run slower and more quiet
Vertical air discharge fans minimizes operating sound
Weather resistant fan motor made to survive in the elements
Highly efficient coil provides excellent heat transfer and low air resistance
Assembled, plumbed, and wired on industrial epoxy-coated steel frame
Complete systems fully run tested under heat load using the WHALE-SOFT™ Testing Platform
Options
Controllers
Electronic Expansion Valves
Strainers & Filtration
Casters
Solenoid Valves
Filter Dryer
Liquid Line Valves
Basin Heaters
Casters
Strainers & Filtration
Contact Us Today!
Have a question? Need a quote? Sales Engineers are standing by to help.
Simply fill out our form, or give us a call at 940-569-4116.
At Whaley Products, Inc. we manufacture quality industrial cooling systems for a wide range of processes and applications. A commitment to precision engineering and innovative design have made Whaley Chillers the choice of Industry Leaders.
Contact a Whaley Sales Engineer today for more information.