Elevated Tower + Heat Transfer/Process Side Pump Tank Skid
The WP-Series Config. 10 manufactured by Whaley Products, Inc. is an elevated closed loop cooling tower with heat transfer/process side skid up to 750 tons. With closed loop towers, the tower water is isolated from the process fluid, therefore allowing you to utilize this system to cool other fluids including glycol, salt water, oil, among others. It also helps maintain a clean process fluid. This configuration includes an open loop tower(s) installed on a subframe and elevated platform in conjunction with a separate skidded indoor heat transfer skid pump tank system for tower side circulation. It also includes a process side pump tank system on the same skid. Included on this indoor heat transfer pump tank skid/process pump tank system is an isolation heat exchanger, tower water reservoir, strainer, cooling tower/heat exchanger circulation pump, process side heat exchanger circulation pump, process pump, process water reservoir and controls. The isolation heat exchanger is specifically chosen for the client’s fluid, flow rate, and temperatures. Comprehensive controls are provided with the system. This closed loop configuration is helpful for customers who want to isolate the process fluid from the tower in instances of high temperatures and process fluids other than water. This configuration is best suited for client’s who need the entire set up to serve their application and have plenty of indoor space available for installation.
cooling towers
Elevated Tower, Heat Transfer and Process Side Pump Tank Skid
This complete closed loop cooling tower system is made up of an Evaporative Induced Draft Cooling Tower Module and a Cooling Tower Heat Transfer Pump Tank System. This unit is an evaporative induced draft cooling tower system, which is typically installed outdoors. The cooling tower is factory mounted on an epoxy coated steel sub-frame with fork slots and lifting eyes with steel legs to elevate the tower. The steel legs allow the cooling tower water to gravity return back to the Cooling Tower Heat Transfer Pump Tank System included in this system. The second component is the Cooling Tower Heat Transfer Pump Tank System, which is typically installed indoors. This system contains two components. The Cold Side Heat Transfer Pump Tank System contains a water reservoir and a pump. The cooling tower heat exchanger circulation pump circulates the heat exchanger and the cooling tower to keep the Cooling Tower Heat Transfer Pump Tank System’s reservoir at the target set point temperature. The Hot Side Pump Tank System contains a water reservoir and two pumps. One heat exchanger circulation pump circulates the cooling tower to keep the Process Side Pump Tank System’s reservoir at the target set point temperature. The process supply pump pulls out of the reservoir, circulates to your downstream application, and returns back to the system’s reservoir.
Elevated Tower, Heat Transfer and Process Side Pump Tank Skid
Use this chart to browse our Elevated Tower, Heat Transfer and Process Side Pump Tank Skid Systems. Unit capacities have been illustrated at various hypothetical site conditions.
Our Sales Engineers are available to assist in choosing the right system for your application and answer any questions you may have.
* Performance Illustrated at Hypothetical Conditions of 95F Ambient, 50% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
** Performance Illustrated at Standard Site Conditions of 95F Ambient, 0% Glycol, Up to 2000 Feet Elevation, 60Hz Power.
*** Performance Illustrated at Hypothetical Conditions of 95F Ambient, 0% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
Contact a Whaley sales engineer to obtain performance ratings at your specific site conditions.
Model | Nominal Capacity (tons) | Nominal Capacity (BTU/hr) | Nominal Capacity (kW) | Air Flow (cfm) | Flow Rate (gpm) | Water Usage (gpm) | Elevation Package | CTHXP @ 34.6 psi (HP) | HXCP @ 17.3 psi (HP) | SP @ 43-50 psi (HP) | Inlet/Outlet (in) | Control Panel | Fan Motor (HP) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WP650-10 & T100-X-PTHXSS-T100-X-2PT | 10 | 150,000 | 43.88 | 3,000 | 30 | 0.30 | YES | 1.5 | 0.75 | 2 | 2 | YES | 0.50 |
WP650-15 & T150-X-PTHXSS-T150-X-2PT | 15 | 225,000 | 65.81 | 3,250 | 45 | 0.45 | YES | 1.5 | 1 | 3 | 2 | YES | 0.50 |
WP850-20 & T150-X-PTHXSS-T150-X-2PT | 20 | 300,000 | 87.75 | 6,000 | 60 | 0.60 | YES | 3 | 1 | 3 | 2 | YES | 0.75 |
WP850-25 & T210-X-PTHXSS-T210-X-2PT | 25 | 375,000 | 109.69 | 6,500 | 75 | 0.75 | YES | 3 | 1.5 | 3 | 2 | YES | 0.75 |
WP1250-30 & T250-X-PTHXSS-T250-X-2PT | 30 | 450,000 | 131.63 | 11,300 | 90 | 0.90 | YES | 3 | 2 | 5 | 2 | YES | 2 |
WP1250-40 & T305-X-PTHXSS-T305-X-2PT | 40 | 600,000 | 175.50 | 12,000 | 120 | 1.20 | YES | 5 | 2 | 5 | 3 | YES | 2 |
WP1550-50 & T305-X-PTHXSS-T305-X-2PT | 50 | 750,000 | 219.38 | 15,000 | 150 | 1.50 | YES | 5 | 2 | 5 | 3 | YES | 3 |
WP1550-60 & T550-X-PTHXSS-T550-X-2PT | 60 | 900,000 | 263.25 | 16,250 | 180 | 1.80 | YES | 5 | 3 | 7.5 | 3 | YES | 3 |
WP1550-75 & T550-X-PTHXSS-T550-X-2PT | 75 | 1,125,000 | 329.06 | 17,500 | 225 | 2.25 | YES | 7.5 | 3 | 10 | 3 | YES | 3 |
WP1850-100 & T1000-X-PTHXSS-T1000-X-2PT | 100 | 1,500,000 | 438.75 | 20,500 | 300 | 3.00 | YES | 10 | 5 | 10 | 3 | YES | 5 |
WP1850-125 & T1000-X-PTHXSS-T1000-X-2PT | 125 | 1,875,000 | 548.40 | 22,700 | 375 | 3.75 | YES | 10 | 7.5 | 15 | 3 | YES | 5 |
WP2-1550-150 & T1550-X-PTHXSS-T1550-X-2PT | 150 | 2,250,000 | 658.13 | 35,000 | 450 | 4.50 | YES | 15 | 7.5 | 15 | 3 | YES | 2ea 3 |
WP2-1850-200 & T1550-X-PTHXSS-T1550-X-2PT | 200 | 3,000,000 | 877.50 | 41,000 | 600 | 6.00 | YES | 20 | 10 | 25 | 4 | YES | 2ea 5 |
WP2-1850-250 & T1550-X-PTHXSS-T1550-X-2PT | 250 | 3,750,000 | 1,096.88 | 45,400 | 750 | 7.50 | YES | 25 | 10 | 30 | 6 | YES | 2ea 5 |
WP3-1850-300 & T2100-X-PTHXSS-T2100-X-2PT | 300 | 4,500,000 | 1,316.25 | 61,500 | 900 | 9.00 | YES | 30 | 15 | 40 | 6 | YES | 3ea 5 |
WP3-1850-375 & T2550-X-PTHXSS-T2550-X-2PT | 375 | 5,625,000 | 1,645.30 | 68,100 | 1,125 | 11.25 | YES | 40 | 15 | 50 | 4 | YES | 3ea 5 |
WP4-1850-400 & T2550-X-PTHXSS-T2550-X-2PT | 400 | 6,000,000 | 1,755.00 | 82,000 | 1,200 | 12.00 | YES | 40 | 20 | 50 | 6 | YES | 4ea 5 |
WP4-1850-500 & T3000-X-PTHXSS-T3000-X-2PT | 500 | 7,500,000 | 2,193.75 | 90,800 | 1,500 | 15.00 | YES | 40 | 25 | 50 | 6 | YES | 4ea 5 |
WP5-1850-625 & T4000-X-PTHXSS-T4000-X-2PT | 625 | 9,375,000 | 2,742.19 | 113,500 | 1,875 | 18.75 | YES | 50 | 30 | 75 | 6 | YES | 5ea 5 |
WP6-1850-750 & T5000-X-PTHXSS-T5000-X-2PT | 750 | 11,250,000 | 3,290.63 | 136,200 | 2,250 | 22.50 | YES | 60 | 30 | 75 | 6 | YES | 6ea 5 |
Standard Features
Options
Controllers
Thermal Wells
Strainers & Filtration
Variable Frequency Drives
Basin Heaters
Electrical Disconnects
Extra Fittings
Tanks
Pumps
Elevation Packages
Contact Us Today!
Have a question? Need a quote? Sales Engineers are standing by to help.
Simply fill out our form, or give us a call at 940-569-4116.
At Whaley Products, Inc. we manufacture quality industrial cooling systems for a wide range of processes and applications. A commitment to precision engineering and innovative design have made Whaley Chillers the choice of Industry Leaders.