Elevated Tower with Pump Tank System 05

The Elevated Cooling Tower with Pump Tank System 05 manufactured by Whaley Products, Inc. is a complete open loop system with pumps, tank, controls and filtration. This configuration can serve applications in ranges from 10 ton to unlimited tonnages. This unit comes with a cooling tower installed on a subframe elevated on steel legs with a separate skidded cooling tower pump tank system. Included on the pump tank is a drain down reservoir tank, cooling tower circulation pump, process pump, strainer, electrical disconnect, and control panel. Included in the controls are on/off switches for the pumps and tower fan(s). It also includes a digital temperature controller that cycles the tower fan based on the indoor pump tank system’s resevoir temperature. This configuration is beneficial for customers in cold weather environments to prevent the tower water from freezing. It is also more suitable for people who have available indoor space to install the pump tank system. For warmer climate installations, the pump tank system can easily be installed outdoor to conserve indoor space while still allowing a large oversized thermal buffer to exist in the system.

Elevated Cooling tower with Pump Tank 05
Elevated Tower with Pump Tank Skid
Elevated Tower Pump Tank

Contact a Whaley Sales Engineer today for more information.
Ten Ton Elevated Cooling Tower with pump tank skid

Elevated Tower with Pump Tank Skid 05

This complete system is made up of an Evaporative Open Loop Induced Draft Cooling Tower Module and a Cooling Tower Pump Tank System. The cooling tower is factory mounted on an epoxy coated steel sub-frame with fork slots and lifting eyes with steel legs to elevate the tower. The steel legs allow the cooling tower water to gravity return back to the Cooling Tower Pump Tank System included in this system. The Cooling Tower Pump Tank System is typically installed indoors, however can be installed outdoors with proper freeze protection and/or insulation. The Cooling Tower Pump Tank System contains a water reservoir and pumps. One pump (cooling tower circulation pump) circulates the cooling tower to keep the Cooling Tower Pump Tank System’s reservoir at the target set point temperature. The other pump (process supply pump) pulls out of the reservoir, circulates to the downstream application, and returns back to the system’s reservoir.

Open Loop Cooling Tower Model 05 Elevated Tower with Pump Tank System

Available Elevated Tower with Pump Tank System 05 Models

Use this chart to browse Evaporative Open Loop Induced Draft Cooling Tower Module and a Cooling Tower Pump Tank System 05. Unit capacities have been illustrated at various hypothetical site conditions.
Our Sales Engineers are available to assist in choosing the right system for your application and answer any questions you may have. * Performance Illustrated at Hypothetical Conditions of 95F Ambient, 50% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power. ** Performance Illustrated at Standard Site Conditions of 95F Ambient, 0% Glycol, Up to 2000 Feet Elevation, 60Hz Power. *** Performance Illustrated at Hypothetical Conditions of 95F Ambient, 0% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power. Contact a Whaley sales engineer to obtain performance ratings at your specific site conditions.

ModelNominal Capacity (tons)Nominal Capacity (BTU/hr)Nominal Capacity (kW)Air Flow (CFM)Flow Rate (GPM)Water Usage Rate (GPM)Sub-Frame (in)Elevation PKGCWP (HP)@ 26.0psiCTSP (HP) @ 43.3psiPump MaterialStrainer Size (in)Inlet/Outlet (in)Control PanelFan Motor
WP650-10 & T100-X-2PT10150,00043.883,000300.30YESYES1.02stainless steel22YES0.50
WP650-15 & T150-X-2PT15225,00065.813,250450.45YESYES1.53stainless steel22YES0.50
WP850-20 & T150-X-2PT20300,00087.756,000600.60YESYES1.53stainless steel22YES0.75
WP850-25 & T210-X-2PT25375,000109.696,500750.75YESYES2.03stainless steel22YES0.75
WP1250-30 & T250-X-2PT30450,000131.6311,300900.90YESYES2.05stainless steel22YES2.00
WP1250-40 & T305-X-2PT40600,000175.5012,0001201.20YESYES5.05stainless steel33YES2.00
WP1550-50 & T305-X-2PT50750,000219.3815,0001501.50YESYES5.05stainless steel33YES3.00
WP1550-60 & T550-X-2PT60900,000263.2516,2501801.80YESYES5.07.5stainless steel33YES3.00
WP1550-75 & T550-X-2PT751,125,000329.0617,5002252.25YESYES5.010stainless steel33YES3.00
WP1850-100 & T1000-X-2PT1001,500,000438.7520,5003003.00YESYES7.510stainless steel44YES5.00
WP1850-125 & T1000-X-2PT1251,875,000548.4022,7003753.75YESYES10.015stainless steel44YES5.00
WP2-1550-150 & T1550-X-2PT1502,250,000658.1335,0004504.50YESYES10.015stainless steel33YES2ea 3.00
WP2-1850-200 & T1550-X-2PT2003,000,000877.5041,0006006.00YESYES15.025cast iron44YES2ea 5.00
WP2-1850-250 & T1550-X-2PT2503,750,0001,096.8845,4007507.50YESYES20.030cast iron66YES2ea 5.00
WP3-1850-300 & T2100-X-2PT3004,500,0001,316.2561,5009009.00YESYES20.040cast iron66YES3ea 5.00
WP3-1850-375 & T2550-X-2PT3755,625,0001,645.3068,1001,12511.25YESYES25.050cast iron44YES3ea 5.00
WP4-1850-400 & T2550-X-2PT4006,000,0001,755.0082,0001,20012.00YESYES25.050cast ironYES4ea 5.00
WP4-1850-500 & T3000-X-2PT5007,500,0002,193.7590,,8001,50015.00YESYES30.050cast ironYES4ea 5.00
WP5-1850-625 & T4000-X-2PT6259,375,0002,742.19113,5001,87518.75YESYES40.075cast ironYES5ea 5.00
WP6-1850-750 & T5000-X-2PT75011,250,0003,290.63136,2002,25022.50YESYES50.075cast ironYES6ea 5.00

Standard Features

Options

Controllers

Thermal Wells

Strainers & Filtration

Variable Frequency Drives

Basin Heaters

Electrical Disconnects

Extra Fittings

Tanks

Pumps

Elevation Packages

Contact Us Today!

Have a question?   Need a quote?  Sales Engineers are standing by to help.

Simply fill out our form, or give us a call at 940-569-4116.

At Whaley Products, Inc. we manufacture quality industrial cooling systems for a wide range of processes and applications.  A commitment to precision engineering and innovative design have made Whaley Chillers the choice of Industry Leaders.

Open Loop Cooling Tower Model 05 Elevated Tower with Pump Tank System
Contact Us
First
Last
Contact a Whaley Sales Engineer today for more information.