RAE High Redundancy Chiller System
High Redundancy Chiller System
High Redundancy Chiller Systems, the RAE-Series manufactured by Whaley Products, Inc. is a modular air-cooled chiller system consisting of multiple SAE-Series Modular Chillers. Frequently, multiple SAE-Series units are selected in conjunction with a C-Series pump tank system to provide a high redundancy chiller system for critical heat load applications. The RAE-Series systems are typically purchased initially with a multiple chiller modules with a pump tank to start with. With the initial setup, WPI can size the pump tank system for unlimited capacity. One of the benefits of the RAE-Series is its redundancy. By using multiple modules, it gives the high redundancy you need for critical heat load applications that cannot have any downtime. This system can be used for any heat load applications due to having no restrictions on capacity. The pump tank system’s reservoir can be sized for whatever your desired volume is which gives you more temperature stability as well as the ability to “store btu/hr” to help minimize chiller size. The RAE-Series coupled with the C-Series Pump Tank System also allows for multiple configurations and flexible design. WPI can provide but are not limited to redundant pumps, variable frequency drives, different tank materials, different plumbing materials (including those for food applications), and many more.
High Redundancy Modular Chiller System
High Redundancy Modular Chiller System, the RAE-Series manufactured by Whaley Products, Inc. is a modular air-cooled chiller system consisting of multiple SAE-Series Modular Chillers. Frequently, multiple SAE-Series units are selected in conjunction with a C-Series pump tank system to provide a high redundancy chiller system for critical heat load applications. The RAE-Series systems are typically purchased initially with a multiple chiller modules with a pump tank to start with. With the initial setup, WPI can size the pump tank system for unlimited capacity. One of the benefits of the RAE-Series is its redundancy. By using multiple modules, it gives the high redundancy you need for critical heat load applications that cannot have any downtime. This system can be used for any heat load applications due to having no restrictions on capacity. The pump tank system’s reservoir can be sized for whatever your desired volume is which gives you more temperature stability as well as the ability to “store btu/hr” to help minimize chiller size. The RAE-Series coupled with the C-Series Pump Tank System also allows for multiple configurations and flexible design. WPI can provide but are not limited to redundant pumps, variable frequency drives, different tank materials, different plumbing materials (including those for food applications), and many more.
The RAE-Series
High Redundancy Modular Chiller System and a Pump Tank System SkidThis high redundancy chiller system is a complete system made up of Modular Air-Cooled Chiller Units and a Pump Tank System Skid. Air-Cooled Modular Chiller Units are included and are typically installed outdoors in order to deflect the heat to the outside atmosphere. The single Pump Tank System Skid will be used in conjunction with the Modular Air-Cooled Chiller Units. The single Pump Tank System Skid is typically installed indoors or outdoors. Indoor and outdoor reservoir insulation packages are available depending on where the skid is to be located. The Pump Tank System Skid contains water/glycol reservoir, pumps, and controls. One pump (chiller circulation pump) circulates the Modular Air-Cooled Chiller Units to keep the Pump Tank System Skid's reservoir tank at the target set point temperature. The other pump (process supply pump) pulls out of the Pump Tank System Skid reservoir, circulates to your downstream application, and returns back to the reservoir.
RAE-Series System Configurations
RAE-Series Multi-Condenser Systems by Capacity
Use this chart to browse our RAE-Series High Redundancy Chiller Systems.
Unit capacities have been illustrated at various hypothetical site conditions.
Our Sales Engineers are available to assist in choosing the right system for your application and answer any questions you may have.
* Performance Illustrated at Hypothetical Conditions of 95F Ambient, 50% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
** Performance Illustrated at Standard Site Conditions of 95F Ambient, 0% Glycol, Up to 2000 Feet Elevation, 60Hz Power.
*** Performance Illustrated at Hypothetical Conditions of 95F Ambient, 0% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAE3D-X-2P100T | 3 | 2 | 7.2 | 100 |
RAE4.5T-X-2P100T | 4.5 | 3 | 10.8 | 100 |
RAE6Q-X-2P100T | 6 | 4 | 14.4 | 100 |
RAE4D-X-2P100T | 4 | 2 | 9.6 | 100 |
RAE6T-X-2P100T | 6 | 3 | 14.4 | 100 |
RAE6D-X-2P100T | 6 | 2 | 14.4 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR8Q-X-2P100T4E | 8 | 4 | 19.2 | 100 |
RAR8D-X-2P100T2E | 8 | 2 | 19.2 | 100 |
RAR9T-X-2P100T3E | 9 | 3 | 21.6 | 100 |
RAR10D-X-2P100T2E | 10 | 2 | 24 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR12Q-X-2P100T4E | 12 | 2 | 7.2 | 100 |
RAR12T-X-2P100T3E | 12 | 3 | 10.8 | 100 |
RAR12D-X-2P100T2E | 12 | 4 | 14.4 | 100 |
RAR15T-X-2P100T3E | 15 | 2 | 9.6 | 100 |
RAR15D-X-2P100T2E | 15 | 3 | 14.4 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR16Q-X-2P100T4E | 16 | 4 | 38.4 | 100 |
RAR18T-X-2P150T3E | 18 | 3 | 43.2 | 150 |
RAR20Q-X-2P100T4E | 20 | 4 | 48 | 100 |
RAR20D-X-2P100T2E | 20 | 2 | 48 | 100 |
RAR20D-X-2P100T4E | 20 | 2 | 48 | 100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR22.5T-X-2P150T3E | 22.5 | 3 | 54 | 150 |
RAR24Q-X-2P100T2E | 24 | 4 | 57.6 | 150 |
RAR25D-X-2P150T2E | 25 | 2 | 60 | 150 |
RAR25D-X-2P150T4E | 25 | 2 | 60 | 150 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR30Q-X-2P150T4E | 30 | 4 | 72 | 150 |
RAR30T-X-2P150T3E | 30 | 3 | 72 | 150 |
RAR30D-X-2P150T2E | 30 | 2 | 72 | 150 |
RAR30D-X-2P150T4E | 30 | 2 | 72 | 150 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR37.5T-X-2P200T3E | 37.5 | 3 | 90 | 200 |
RAR40Q-X-2P200T4E | 40 | 4 | 96 | 200 |
RAR40D-X-2P200T2E | 40 | 2 | 96 | 200 |
RAR40D-X-2P200T4E | 40 | 2 | 96 | 200 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR45T-X-2P305T3E | 45 | 3 | 108 | 305 |
RAR50Q-X-2P305T4E | 50 | 4 | 120 | 305 |
RAR50D-X-2P305T2E | 50 | 2 | 120 | 305 |
RAR50D-X-2P305T4E | 50 | 2 | 120 | 305 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR60Q-X-2P305T4E | 60 | 4 | 144 | 305 |
RAR60T-X-2P305T3E | 60 | 3 | 144 | 305 |
RAR60D-X-2P305T2E | 60 | 2 | 144 | 305 |
RAR60D-X-2P305T4E | 60 | 2 | 144 | 305 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR75T-X-2P500T3E | 75 | 3 | 180 | 500 |
RAR75T-X-2P500T6E | 75 | 3 | 180 | 500 |
RAR80Q-X-2P500T4E | 80 | 4 | 192 | 500 |
RAR80D-X-2P500T2E | 80 | 2 | 192 | 500 |
RAR80D-X-2P500T4E | 80 | 2 | 192 | 500 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR90T-X-2P500T3E | 90 | 3 | 216 | 500 |
RAR90T-X-2P500T6E | 90 | 3 | 216 | 500 |
RAR100F-X-2P500T5E | 100 | 5 | 240 | 500 |
RAR100Q-X-2P500T4E | 100 | 4 | 240 | 500 |
RAR100D-X-2P500T2E | 100 | 2 | 240 | 500 |
RAR100D-X-2P500T4E | 100 | 2 | 240 | 500 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR120S-X-2P750T6E | 120 | 6 | 288 | 750 |
RAR120Q-X-2P750T4E | 120 | 4 | 288 | 750 |
RAR120T-X-2P750T3E | 120 | 3 | 288 | 750 |
RAR120T-X-2P750T6E | 120 | 3 | 288 | 750 |
RAR130D-X-2P750T2E | 130 | 2 | 312 | 750 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR140D-X-2P750T4E | 140 | 2 | 336 | 750 |
RAR150T-X-2P750T3E | 150 | 3 | 360 | 750 |
RAR150T-X-2P750T6E | 150 | 3 | 360 | 750 |
RAR160Q-X-2P1000T4E | 160 | 4 | 384 | 1000 |
RAR160D-X-2P1000T4E | 160 | 2 | 384 | 1000 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR180D-X-2P1000T4E | 180 | 2 | 432 | 1000 |
RAR195T-X-2P1000T3E | 195 | 3 | 468 | 1000 |
RAR200Q-X-2P1000T4E | 200 | 4 | 480 | 1000 |
RAR200Q-X-2P1000T8E | 200 | 4 | 480 | 1000 |
RAR200D-X-2P1000T4E | 200 | 2 | 480 | 1000 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR210T-X-2P1550T6E | 210 | 3 | 504 | 1550 |
RAR230D-X-2P1550T4E | 230 | 2 | 552 | 1550 |
RAR240T-X-2P1550T6E | 240 | 3 | 576 | 1550 |
RAR260Q-X-2P1550T4E | 260 | 4 | 624 | 1550 |
RAR260D-X-2P1550T4E | 260 | 2 | 624 | 1550 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR270T-X-2P1550T6E | 270 | 3 | 648 | 1550 |
RAR280Q-X-2P1550T8E | 280 | 4 | 672 | 1550 |
RAR300T-X-2P1550T6E | 300 | 3 | 720 | 1550 |
RAR320Q-X-2P2100T8E | 320 | 4 | 768 | 2100 |
RAR345T-X-2P2100T6E | 345 | 2 | 828 | 2100 |
Full System Model Number | Total Nomimal Tonnage | Quantity of Condensers | Flow Rate (gpm) | Tank Volume (gal) |
---|---|---|---|---|
RAR360Q-X-2P2100T8E | 360 | 4 | 864 | 2100 |
RAR390T-X-2P2100T6E | 390 | 3 | 936 | 2100 |
RAR400Q-X-2P2100T8E | 400 | 4 | 960 | 2100 |
RAR460Q-X-2P2500T8E | 460 | 4 | 1104 | 2500 |
RAR520Q-X-2P2500T8E | 520 | 4 | 1248 | 2500 |
Contact a Whaley Sales Engineer today for more information.
Standard Features
High Efficient R-410A Refrigerant
Copeland Scroll compressor(s)
Insulated stainless steel copper-brazed plate evaporator(s) (Cupre Nickel available)
Thermostatic expansion valve, filter drier, sight glass installed on refrigerant lines
Service ports and valves
NEMA 4 Control panel with digital temperature controller
High and low pressure safety
Single point power connection
Direct drive fan(s) made to run slower and more quiet
Weather resistant fan motor made to survive in the elements
Highly efficient coil provides excellent heat transfer and low air resistance
Assembled, plumbed, and wired on industrial epoxy-coated steel frame
Options
Controllers
Electronic Expansion Valves
Strainers & Filtration
Casters
Solenoid Valves
Filter Dryer
Liquid Line Valves
Basin Heaters
Casters
Strainers & Filtration
Contact Us Today!
Have a question? Need a quote? Sales Engineers are standing by to help.
Simply fill out our form, or give us a call at 940-569-4116.
At Whaley Products, Inc. we manufacture quality industrial cooling systems for a wide range of processes and applications. A commitment to precision engineering and innovative design have made Whaley Chillers the choice of Industry Leaders.
Contact a Whaley Sales Engineer today for more information.