Elevated Closed Loop Two Skid System 08
The Elevated Closed Loop Cooling Tower Two Skid System 08 manufactured by Whaley Products, Inc. is a closed loop tower system for potable applications. This configuration can serve a wide range of applications in unlimited capacity ranges. With closed loop tower systems, the tower water is isolated from the process fluid, therefore allowing you to utilize this system to cool process fluids such as glycol, hot quench tank water, salt water, oil, among others. It also helps maintain a clean process fluid. This configuration includes an open loop tower(s) installed on a subframe and elevated platform in conjunction with a separate skidded indoor heat transfer skid pump tank system. Included on this indoor heat transfer pump tank skid is an isolation heat exchanger, tower water reservoir, strainer, cooling tower circulation pump, heat exchanger circulation pump, and controls. The isolation heat exchanger is specifically chosen for the client’s fluid, flow rate, and temperatures. Included in the controls are on/off switches for the pump and tower fan(s). It also includes a digital temperature controller that cycles the tower fan based on tower basin temperature. This configuration is helpful for customers who want to keep their buffer reservoir, pumps, and heat exchanger indoors to protect it against freezing in cold climate regions while allowing flexibility to still achieve a true closed loop design.
Elevated Closed Loop Cooling Tower Two Skid System 08
This complete elevated closed loop two skid cooling tower system is made up of an Evaporative Induced Draft Cooling Tower Module and a Cooling Tower Heat Transfer Pump Tank System. This unit is an evaporative induced draft cooling tower system, which is typically installed outdoors. The cooling tower is factory mounted on an epoxy coated steel sub-frame with fork slots and lifting eyes with steel legs to elevate the tower. The steel legs allow the cooling tower water to gravity return back to the Cooling Tower Heat Transfer Pump Tank System included in this system. The second component is the Cooling Tower Heat Transfer Pump Tank System, which is typically installed indoors. This system contains a water reservoir, plate and frame heat exchanger, and pumps. One pump (cooling tower circulation pump) circulates the cooling tower to keep the Cooling Tower Heat Transfer Pump Tank System’s reservoir at the target set point temperature. The other pump (heat exchanger circulation pump) pulls out of the reservoir, circulates the plate and frame heat exchanger, and returns back to the system’s reservoir.
Available Elevated Closed Loop Cooling Tower Two Skid System 08 Models
Use this chart to browse our Elevated Closed Loop Cooling Tower Two Skid System 08 models. Unit capacities have been illustrated at various hypothetical site conditions.
Our Sales Engineers are available to assist in choosing the right system for your application and answer any questions you may have.
* Performance Illustrated at Hypothetical Conditions of 95F Ambient, 50% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
** Performance Illustrated at Standard Site Conditions of 95F Ambient, 0% Glycol, Up to 2000 Feet Elevation, 60Hz Power.
*** Performance Illustrated at Hypothetical Conditions of 95F Ambient, 0% Propylene Glycol, Up to 2000 Feet Elevation, 60Hz Power.
Contact a Whaley sales engineer to obtain performance ratings at your specific site conditions.
Model | Nominal Capacity (tons) | Nominal Capacity (BTU/hr) | Nominal Capacity (kW) | Air Flow (cfm) | Flow Rate (gpm) | Water Usage (gpm) | Elevation Package | CTP @ 34.6 psi (HP) | HXCP @ 17.3 psi (HP) | Inlet/Outlet (in) | Control Panel | Fan Motor (HP) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
WP650-10 & T100-X-2PTHXSS | 10 | 150,000 | 43.88 | 3,000 | 30 | 0.30 | YES | 1.5 | 0.75 | 2 | YES | 0.50 |
WP650-15 & T150-X-2PTHXSS | 15 | 225,000 | 65.81 | 3,250 | 45 | 0.45 | YES | 1.5 | 1 | 2 | YES | 0.50 |
WP850-20 & T150-X-2PTHXSS | 20 | 300,000 | 87.75 | 6,000 | 60 | 0.60 | YES | 3 | 1 | 2 | YES | 0.75 |
WP850-25 & T210-X-2PTHXSS | 25 | 375,000 | 109.69 | 6,500 | 75 | 0.75 | YES | 3 | 1.5 | 2 | YES | 0.75 |
WP1250-30 & T250-X-2PTHXSS | 30 | 450,000 | 131.63 | 11,300 | 90 | 0.90 | YES | 3 | 2 | 2 | YES | 2 |
WP1250-40 & T305-X-2PTHXSS | 40 | 600,000 | 175.50 | 12,000 | 120 | 1.20 | YES | 5 | 2 | 3 | YES | 2 |
WP1550-50 & T305-X-2PTHXSS | 50 | 750,000 | 219.38 | 15,000 | 150 | 1.50 | YES | 5 | 2 | 3 | YES | 3 |
WP1550-60 & T550-X-2PTHXSS | 60 | 900,000 | 263.25 | 16,250 | 180 | 1.80 | YES | 5 | 3 | 3 | YES | 3 |
WP1550-75 & T550-X-2PTHXSS | 75 | 1,125,000 | 329.06 | 17,500 | 225 | 2.25 | YES | 7.5 | 3 | 3 | YES | 3 |
WP1850-100 & T1000-X-2PTHXSS | 100 | 1,500,000 | 438.75 | 20,500 | 300 | 3.00 | YES | 10 | 5 | 3 | YES | 5 |
WP1850-125 & T1000-X-2PTHXSS | 125 | 1,875,000 | 548.40 | 22,700 | 375 | 3.75 | YES | 10 | 7.5 | 3 | YES | 5 |
WP2-1550-150 & T1550-X-2PTHXSS | 150 | 2,250,000 | 658.13 | 35,000 | 450 | 4.50 | YES | 15 | 7.5 | 3 | YES | 2ea 3 |
WP2-1850-200 & T1550-X-2PTHXSS | 200 | 3,000,000 | 877.50 | 41,000 | 600 | 6.00 | YES | 20 | 10 | 4 | YES | 2ea 5 |
WP2-1850-250 & T1550-X-2PTHXSS | 250 | 3,750,000 | 1,096.88 | 45,400 | 750 | 7.50 | YES | 25 | 10 | 6 | YES | 2ea 5 |
WP3-1850-300 & T2100-X-2PTHXSS | 300 | 4,500,000 | 1,316.25 | 61,500 | 900 | 9.00 | YES | 30 | 15 | 6 | YES | 3ea 5 |
WP3-1850-375 & T2550-X-2PTHXSS | 375 | 5,625,000 | 1,645.30 | 68,100 | 1,125 | 11.25 | YES | 40 | 15 | 4 | YES | 3ea 5 |
WP4-1850-400 & T2550-X-2PTHXSS | 400 | 6,000,000 | 1,755.00 | 82,000 | 1,200 | 12.00 | YES | 40 | 20 | 6 | YES | 4ea 5 |
WP4-1850-500 & T3000-X-2PTHXSS | 500 | 7,500,000 | 2,193.75 | 90,800 | 1,500 | 15.00 | YES | 40 | 25 | 6 | YES | 4ea 5 |
WP5-1850-625 & T4000-X-2PTHXSS | 625 | 9,375,000 | 2,742.19 | 113,500 | 1,875 | 18.75 | YES | 50 | 30 | 6 | YES | 5ea 5 |
WP6-1850-750 & T5000-X-2PTHXSS | 750 | 11,250,000 | 3,290.63 | 136,200 | 2,250 | 22.50 | YES | 60 | 30 | 6 | YES | 6ea 5 |
Standard Features
Options
Controllers
Thermal Wells
Strainers & Filtration
Variable Frequency Drives
Basin Heaters
Electrical Disconnects
Extra Fittings
Tanks
Pumps
Elevation Packages
Contact Us Today!
Have a question? Need a quote? Sales Engineers are standing by to help.
Simply fill out our form, or give us a call at 940-569-4116.
At Whaley Products, Inc. we manufacture quality industrial Elevated Closed Loop Cooling Tower Two Skid 08 systems for a wide range of processes and applications. A commitment to precision engineering and innovative design have made Whaley Chillers the choice of Industry Leaders.